Range 12.X - Filtering Ventilation Safety Cabinets
CONFORMITY
- Adsorption capacity in compliance with the NF X 15-211 norm.
- Large warning labels in compliance with ISO 3864 and NF X08.003 norms, 92/58/CEE European directive.
- In compliance with the health regulation articles (R5132-66 and R5132-68).
- Electric fan in compliance with CE specifications.
- Tested and approved by MPA DRESDEN laboratory.
ADVANTAGES
- Cabinet delivered ready to use.
- Independent cabinet ensuring perfect security.
- Elimination of dangerous vapours.
- No need of connection to an exhausting system. No modification of building structure required.
- Easy sight of the stored products.
- Perforated shelves allowing liquids flow in case of discharge.
- Ventilation system with lighting control.
- Window control for presence of the filter adapted to your needs.
- Control of the saturation level with reactive coded tubes.
- Specialised high efficiency actived charcoal filter, in compliance with the NF X 15-211 norm, treated following chemical products stored.
- Dust pre-filter, 92% efficienty with less then 3 µm particles.
- Easy chane of actived charcoal cell.
TECHNICAL SPECIFICATION
Storage Compartment
- Buit in 15/10th steel with white epoxy paint (RAL 9010).
- Large glazed door with framing.
- 4 perforated shelves adjustable in height.
- Double air inlet at the bottom.
- Key-locking system.
- Drawer/retention tank at the bottom with absorbing mat.
Ventilation / Filtration Compartment
- Buit in 15/10th steel with white epoxy paint (RAL 9010).
- Noiseless fan : 220 volts - 50 Hz - 0,2 A - 47 watts; flow: 200 m3/h; IP20 protection, sound level 49 dB(A); delivered with cable and plug.
OPTIONS
- Additional shelf.
- Actived charcoal filters: The cabinets are delivered without actived charcoal filter. You must to select one in the table (at the bootm of this page) depending on your products storage.
- Control of filter saturation level by FILTRALARM:
- Control lead.
- Monitoring system to control the air velocity across the filter.
- Adjustement allowing the detection of filter saturation level and faulty air flow.
- Sound alarm indicating a malfunction in the device.
- Light alarm system.
- Control of filter saturation level by REACTIVE TUBES:
- Control port on the side of the cabinet.
- Use of a manual pump.
- Control of efficienty of active coal filter’s saturation level by observing the tubes.
STORAGE CAPACITY
- 1 shelf : 35 bottles of 1 litre or 15 bottles of 2,5 litres.
- 1 half-shelf : 15 bottles of 1 litre or 7 bottles of 2,5 litres.
WARNING!
- For safety reasons (chemical reactions between incompatible products) the products of different families must be stored separateky.
Reference |
Description |
Dimensions HxWxD (mm) |
Number of shelves |
Number of base trough |
Storage capacity (bottles) 1L or 2,5L |
Weight (kg) |
To
connect |
Filtering ventilation |
Organics |
Corrosives |
AF2X |
AF2X
+ ORG300 |
AF2X
+ COR300 |
1
door cabinet 1 compartment |
External 1900x800x545 Internal 1660x780x500 |
4 |
1 |
140
ou 60 |
140 |
AF2-2X |
AF2-2X + ORG300 |
AF2-2X + COR300 |
1
door cabinet 2 compartments |
External 1900x800x545 Internal (2x)1660x380x500 |
8
half-shelves |
2 |
120
ou 56 |
150 |
AF4-2X |
AF4-2X + ORG300 |
AF4-2X + COR300 |
2
doors cabient with 2 compartments |
External 1950x1600x545 Internal (2x)1660x780x500 |
8 |
2 |
280
ou 120 |
280 |
AF4-3X |
AF4-3X + ORG300 |
AF4-3X + COR300 |
2
doors cabinets with 3 compartments |
External 1950x1600x545 Internal (1x)1660x780x500
(x2) 1660x380x500 |
4 + 8
half-shelves |
3 |
260
ou 116 |
290 |
AF4-4X |
AF4-4X + ORG300 |
AF4-4X + COR300 |
2
doors cabinets with 4 compartments |
External 1950x1600x545 Internal (x4) 1660x380x500 |
16
half-shelves |
4 |
240
ou 112 |
300 |
CAUTION!
- The cabinets are delivered without actived charcoal filter. You have to select one in the table bellow depending on the products you store.
- The actived charcoal filter must be changed at least once a year.
Reference |
Description |
Dimensions |
Weight (kg) |
BET
Surface (m2/g) |
Grading (mm) |
Adsorption
capacity (g) |
CCl4 |
HCl |
ORG300 |
Actived charcoal filter for organic vapours (yellow) |
70x730x380 |
14 |
1100 |
4,75-2,36 |
- |
1300 |
COR300 |
Actived charcoal filter for corrosive vapours (blue) |
70x730x380 |
15 |
1250 |
4,75-2,36 |
2840 |
- |
SFA2 |
Filteralarm (to order imperatively with cabinet) |
- |
- |
- |
- |
- |
PMAF |
Manual pump |
0,4 |
- |
- |
- |
- |
TROR |
Pack of 10 reactive tubes for “organic tests” |
0,08 |
- |
- |
- |
- |
TRAC |
Pack
of 10 reactive tubes for “corrosive tests” |
0,08 |
- |
- |
- |
- |
TROA |
Pack
of 5 reactive tubes for “organic tests” and 5
reactive tubes for “corrosive tests” |
0,08 |
- |
- |
- |
- |
ESAF |
Additional half-shelf for AF2-2X, AF4-3X et AF4-4X |
3 |
- |
- |
- |
- |
ESAF2 |
Additional shelf for AF2X, AF4-2X et AF4-3X |
5 |
- |
- |
- |
- |
The manufacturer keeps the right to modify technical characteristics without notice. Edition 11/2008.